Puncture Needles

Request Order

Fill this form to buy product. Our team will be in touch with you in less than 24h.

Description

Labotect ovarian biopsy needles and sets are developed for medical use in the field of assisted reproduction.

Advantages:

  • Needles and sets for follicular puncture
  • Facet bevel
  • Ergonomic handle
  • Grinded or corroded echo marking
  • Validated ETO-sterilisation
  • MEA / LAL tested
  • Medical device class IIa

(Picture shows needles with grinded echo marking on the left side and with corroded echo marking on the right side)

Options

Single lumen puncture sets
with corroded echo marking, without flushing tube:

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on plug              
13441 300 1.4 / 17 14 1300 1000 yes
15138 330 1.0 / 19 14 1300 1000 yes
16783 300 1.4 / 17 14 800 800 yes
16785 330 1.0 / 19 14 800 800 yes

Single lumen puncture sets
with corroded echo marking and flushing tube:

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on flushing tube
13443 300 1.4 / 17 14 1300 1000 yes

Length of tubing for flushing: 1000 mm

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on flushing tube
16445 300 1.4 / 17 14 750 30 yes

Length of tubing for flushing: 750 mm

Single lumen puncture sets
with grinded echo marking, without flushing tube:

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on plug
13438 300 1.4 / 17 14 1300 1000 yes
13451* 300 1.4 / 17 14 1300 1000 no
13452* 300 1.4 / 17 14 500 1000 no
13452L* 300 1.4 / 17 14 1000 1000 no

*with firm tubing

Double lumen puncture sets
with grinded echo marking and flushing tube:

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on flushing tube
13463 330 1.6 / 16 14 390 1000 yes

Length of tubing for flushing: 350 mm

REF Needle length (mm) Outer diameter of the needle (mm / G) Plug for tubes with … ml Length of tubing from needle to plug (mm) Length of tubing from plug to aspirator (mm) Luer connection on flushing tube
16784 330 1.6 / 16 14 800 800 yes

Length of tubing for flushing: 800 mm

Reviews

There are no reviews yet.

Be the first to review “Puncture Needles”

Your email address will not be published. Required fields are marked *